Region: All States
Assessor Question:
When ceiling mounted vent for heating & cooling has been nominated in a bathroom, that room could no longer be considered an unconditioned room? It would become a daytime zone. Is that correct?
The same vent is in the Ensuite, would this make it a daytime zone too?
TechLink Response:
- The inclusion of documentation that indicates fixed heating and/or cooling reticulation as part of a total dwelling system servicing bathrooms triggers the requirement for those rooms to be zoned as conditioned spaces even if they have openable windows.
- Ensuite bathrooms accessed through a bedroom are night time conditioned zones regardless of whether they have windows or fixed heating/cooling systems.
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article