Zoning: Ensuite question.

Created by Vicki Marshall, Modified on Thu, 10 Nov 2022 at 11:34 AM by Vicki Marshall

Region: All States


Assessor Question:


When ceiling mounted vent for heating & cooling has been nominated in a bathroom, that room could no longer be considered an unconditioned room? It would become a daytime zone. Is that correct?  


The same vent is in the Ensuite, would this make it a daytime zone too? 


TechLink Response:


  • The inclusion of documentation that indicates fixed heating and/or cooling reticulation as part of a total dwelling system servicing bathrooms triggers the requirement for those rooms to be zoned as conditioned spaces even if they have openable windows. 
  • Ensuite bathrooms accessed through a bedroom are night time conditioned zones regardless of whether they have windows or fixed heating/cooling systems.