Satellite Studio - Converted Shipping Container

Created by Vicki Marshall, Modified on Fri, 3 Mar, 2023 at 2:23 PM by Vicki Marshall


Region: All States


Assessor Question:


I was initially asked to do a Section J Report on a detached converted shipping container and now the clients tell me that the Certifier wants to assess it as a Class 1 as its going to be a personal gym.

 

Can I do a NatHERS assessment on it and treat it similar to a studio apartment/bedsit for the zoning?


TechLink Response:


  • It is not possible to use a NatHERS Assessment for this building without a kitchen.
  • Being a satellite portion of a class 1a Dwelling without a kitchen the simple method to demonstrate compliance for building fabric energy efficiency will be with an Elemental Deemed to Satisfy assessment.
  • The alternatives to an Elemental DtS assessment are a Performance Assessment or Expert Opinion.
  • In those cases, it is necessary to demonstrate a level of performance equal to or better than the DtS results.


Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article