Satellite Studio - Converted Shipping Container

Created by Vicki Marshall, Modified on Fri, 03 Mar 2023 at 02:23 PM by Vicki Marshall


Region: All States


Assessor Question:


I was initially asked to do a Section J Report on a detached converted shipping container and now the clients tell me that the Certifier wants to assess it as a Class 1 as its going to be a personal gym.

 

Can I do a NatHERS assessment on it and treat it similar to a studio apartment/bedsit for the zoning?


TechLink Response:


  • It is not possible to use a NatHERS Assessment for this building without a kitchen.
  • Being a satellite portion of a class 1a Dwelling without a kitchen the simple method to demonstrate compliance for building fabric energy efficiency will be with an Elemental Deemed to Satisfy assessment.
  • The alternatives to an Elemental DtS assessment are a Performance Assessment or Expert Opinion.
  • In those cases, it is necessary to demonstrate a level of performance equal to or better than the DtS results.