Class 2: Modelling a basement in FirstRate5

Created by Vicki Marshall, Modified on Tue, 29 Nov 2022 at 10:29 AM by Vicki Marshall


Region: All States


Assessor Question:


I have been appointed to provide an energy rating reports for 8 double and triple storey units located mostly over a common garage. There is no direct access in between units and garage. The access to the garage is from the outside and is shared by all units.
 
I am modelling Units as a Class 2 dwellings and I have included garage in modelling as a basement. I have assigned ground floor connect floor – as drawn and garage ceiling as ceiling.


TechLink Response:


  1. If the basement carpark is specified as Dwelling above an underground car park (e.g. a car park which is less than 50 per cent open to the outdoor air and with more than 50 per cent wall area adjacent to earth) model it as a shared basement zone.
  2. If not model the dwelling's ground floor as elevated as per the NatHERS Technical Note table ble



Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select atleast one of the reasons

Feedback sent

We appreciate your effort and will try to fix the article