Parti Walls

Created by Vicki Marshall, Modified on Mon, 07 Nov 2022 at 12:34 PM by Vicki Marshall


Region: All States


Assessor Question


Can you please clarify when modelling if a "full" parti wall should be used (per dwelling) or "half" of the parti wall (per dwelling) 


TechLink Response


  • The NatHERS model requires the full assembly details of any construction surrounding the dwelling being rated.
  • The thermal mass of an assembly as well as thermal heat flow resistance are critical.
  • Selection of Neighbour for elements shared with an adjoining dwellings just sets the thermostat for the ambient conditions of the volume adjoining the subject dwelling.
  • The Neighbour designation means that heat flow is effectively zero because the temperature on either side of the element is nominally the same.

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select atleast one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article